2018, Cilt 10, Sayı 2, Sayfa(lar) 067-069
Foley sound broken and retained in bladder after traumatic catheter removal
Hasan Soydan, A.Kenan Karademir
Maltepe Üniversitesi, Üroloji A.D. , İSTANBUL, Türkiye
Keywords: broken, Foley, sound

Urethral Foley catheterisation is a common procedure that performed on hospitalized patients. It results a in number of infectious and noninfectious complications. We present a case of a 79-year old man with known mental illness who extracted his urethral catheter traumaticly, due to baloon inflated. Foley catheter had broken and its distal part left in the bladder. We argued this condition and it’s treatment in the current article.